کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6727089 | 1428914 | 2018 | 58 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A review on effect of geometrical, flow and soil properties on the performance of Earth air tunnel heat exchanger
ترجمه فارسی عنوان
بررسی اثر خواص هندسی، جریان و خاک بر عملکرد مبدل حرارتی تونل هوا در زمین
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
Ground source heat exchanger1-DETVhEPCSAHGSHeACCBTMSTPPpDecAir cooled condenserCFMEAHEGHPsHETSEarth Air Tunnel Heat ExchangerPipe lengthEarth–Air Heat ExchangerGCHEGround Coupled Heat ExchangerThermal Response TestsCOPVCCSRCHDPEGSHPPCMGHEPV/T - PV / TACh - آهSolar air heater - بخاری هوا خورشیدیWind tower - برج بادair changes per hour - تغییرات هوا در ساعت استHVAC - تهویه مطبوعBuilding thermal mass - جسم حرارتی ساختمانEAT - خوردنsolar chimney - دودکش خورشیدیRelative humidity - رطوبت نسبیcoefficient of performance - ضریب عملکردintermittent operation - عملیات متناوبTransient operation - عملیات گذراPhotovoltaic/thermal - فتوولتائیک / حرارتیMild steel - فولاد خفیفGround heat exchanger - مبدل حرارتی زمینیHorizontal ground heat exchanger - مبدل حرارتی زمینی افقیPhase change material - مواد تغییر فاز دهندهSolar thermal power plant - نیروگاه حرارتی خورشیدیHigh-density polyethylene - پلی اتیلن با چگالی بالاPVC - پلیوینیل کلراید یا پیویسیground source heat pump - پمپ حرارتی با منبع زمینی، پمپ حرارتی زمینگرماییGeothermal heat pumps - پمپ های حرارتی ژئوترمالSupercritical Rankine cycle - چرخه رنکین فوق بحرانیVapor compression cycle - چرخه فشرده سازی بخارpoly vinyl chloride - کلرید پلی وینیلEvaporative cooler - کولر تبخیریHeating, ventilation and air-conditioning - گرمایش، تهویه و تهویه مطبوعOne dimensional - یک بعدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
The principal drivers that led to the high growth rate in the renewable energy market in developing countries over the past twenty years include not only the dwindling fossil reserves, exorbitant increase in the price of crude oil, widening energy deficit, but also the extravagant lifestyle of profligate consumers of energy. Nearly one-third of total primary energy is consumed for the purpose of space cooling and heating. Renewable and passive systems can reduce the building cooling and heating energy demand. Earth air tunnel heat exchanger system is one of the promising technique used for space cooling and heating nowadays, thus reduce fossil fuel based energy demand as well as greenhouse gas emission, but its use has been restrained owing to its poor performance, land area requirement and financial viability. Various experimental, analytical and simulation studies have been conducted in last few decades to investigate the various parameters that may enhance its performance. In this article, the effect of thermo-physical parameters of soil, thermal and flow parameters of air, geometrical and material properties of pipe, different modes of operation on the performance of earth air tunnel heat exchanger systems have been critically reviewed. Following thorough review of the articles, it is concluded that if EATHE system is developed with proper design guidelines, then it may facilitate sufficient space heating and cooling with significant energy savings.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 176, 1 October 2018, Pages 120-138
Journal: Energy and Buildings - Volume 176, 1 October 2018, Pages 120-138
نویسندگان
Kamal Kumar Agrawal, Ghanshyam Das Agrawal, Rohit Misra, Mayank Bhardwaj, Doraj Kamal Jamuwa,