کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7044931 | 1457088 | 2018 | 30 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
An experimental study on the hydrodynamic performance of the water-wall system of a 600â¯MW supercritical CFB boiler
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی شیمی
جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
The temperature distribution on the backside of the water-wall tubes in the first 600â¯MW CFB boiler operating at 60%, 80% and 100% of the boiler Maximum Continuous Rating (MCR) loads was experimentally determined and the thermal-hydrodynamic performance of water-wall system based on the mass and energy equations using the measured temperature was calculated. The results showed that the temperature of the water-wall tubes increased as the furnace height increased, showing a positive response characteristic in the water-wall system. However, the temperature of the water-wall tubes in the upper furnace was obviously declined at the places where the superheaters and cyclone separator inlet-channels were arranged. This suggests that the arrangement of the heat-transfer surfaces in the upper furnace was significantly influenced the temperature distribution of the water-wall tubes. Meanwhile, the calculated total pressure-drop and mass flux in the water-wall system increased as the boiler's load raised, showing an energy-efficiency for the vertical once-through boiler. In addition, the metal temperature was calculated to check the working condition of the water-wall tubes and the results showed the highest metal temperature of 426.3â¯Â°C of the water-wall tubes was found at the tip of the fin at 100% MCR. This temperature was far below the permissible temperature of the metal, implying that a safe working condition of the metal at three loads was guaranteed. Nonetheless, analysis into the heat-transfer characteristics of the water in the water-wall reflects that the water temperature in the water-wall at 80% MCR load was adjacent to the boundary of the large specific-heat region, implying that heat-transfer deterioration was more likely to occur at such condition. Therefore, the metal temperature of the water-wall tubes operating at 80% MCR load requires the most concern and monitor to avoid overheating of the water-wall tubes.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 141, August 2018, Pages 280-287
Journal: Applied Thermal Engineering - Volume 141, August 2018, Pages 280-287
نویسندگان
Ye Chen, Xiaofeng Lu, Wenqing Zhang, Quanhai Wang, Sida Chen, Xuchen Fan, Jianbo Li,