کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7049262 1457160 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Numerical analysis of the curvature effects on Ranque-Hilsch vortex tube refrigerators
ترجمه فارسی عنوان
تجزیه و تحلیل عددی اثر منحنی بر روی یخچالهای لوله ی گرداب رانک-هیلش
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
چکیده انگلیسی
In this paper, the effect of curvature on the performance of vortex tubes is investigated numerically. The study was conducted on curvature angles of 0 and 110°. The model is three dimensional and utilizes the RNG k-ɛ turbulence model for determining the flow and temperature fields. The CFD model is verified through comparison with experimental data reported by the authors previously. The code was then utilized to study the effects of radius and angle of curvature on the performance of vortex tube. The results show that the efficiency of straight vortex tube is higher than the curved vortex tube with angle of 110°. The actual values and CFD model results indicated that CFD model can be successfully used for the determination of heating and cooling performances of curvature effects on Ranque-Hilsch vortex tube.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 65, Issues 1–2, April 2014, Pages 176-183
نویسندگان
, , , ,