کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
705829 | 891367 | 2009 | 11 صفحه PDF | دانلود رایگان |

The aim of this paper is to present and validate a methodology for diagnosing rotor asymmetries in cage motors, based on the analysis of the stator startup current. The method consists of the extraction of a harmonic component introduced by this fault – the left sideband component – from the stator startup current. Two alternative techniques developed by different research groups are proposed for the transient extraction of this component; the digital low-pass filtering (DLPF) and the discrete wavelet transform (DWT). Both approaches are applied to three different industrial motors ranging from 1.1 to 450 kW. A detailed explanation of the physical basis of the method and comments related to the application scope of the approach are also given. The results show the robustness of both approaches for the reliable diagnosis of the fault and suggest a clear potentiality for extending the methodology to the detection of other types of faults introducing components dependant on the slip.
Journal: Electric Power Systems Research - Volume 79, Issue 8, August 2009, Pages 1181–1191