کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7207109 1469064 2018 32 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A new mechanical indentation framework for functional assessment of articular cartilage
ترجمه فارسی عنوان
چارچوب عقیم سازی مکانیکی جدید برای بررسی عملکرد غضروف مفصلی
کلمات کلیدی
غضروف مفصلی، درگیری مکانیکی، ارزیابی غضروف، تغییر شکل، بهبود، ورم، تجزیه و تحلیل چند متغیره، سونوگرافی، دژنراسیون غضروف، کاهش پروتئول گلیکان،
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
چکیده انگلیسی
The conventional mechanical properties of articular cartilage, such as compressive stiffness, have been shown to have limited capacity to distinguish visually normal from degraded cartilage samples. In this study, a new mechanical indentation framework for assessing functional properties of articular cartilage during loading/unloading, i.e. deformation and recovery, was established. The capacity of a ring-shaped indenter integrated with an ultrasound transducer to distinguish mechanically intact from proteoglycan-depleted tissue was investigated. To achieve this, normal and enzymatically degraded bovine osteochondral samples were subjected to loading/unloading while the response of the tissue at the middle was captured by ultrasound at the same time. The enzymatic degradation model was characterized by amount of proteoglycan content, glycosaminoglycan release and proteomic analysis. The mechanical response of a wider continuum of articular cartilage in the loaded area and its surrounding region was captured in this framework leading to investigate two parameters, L and TS, related to the surrounding tissue of the loaded area for functional assessment of cartilage. L is the distance between the ultrasound transducer and articular cartilage surface and TS is the transient strain of articular cartilage during loading and unloading. Classification Analysis based on Principal Component Analysis was used to investigate the capacity of the new parameters to assess the functionality of the tissue. Multivariate statistics based on Partial Least Squares regression was employed to identify the correlation between the response of the tissue in the indented area and its surrounding cartilage. The results of this study indicate that L during loading (deformation) can differentiate normal and mildly proteoglycan-depleted samples from severely depleted samples and L during unloading (recovery) can distinguish between normal and proteoglycan-depleted tissue. However, TS during deformation and recovery is unable to discriminate normal cartilage samples from proteoglycan-depleted tissue. The results also demonstrate a strong correlation between mechanical properties of the loaded area with the response of its surrounding cartilage during recovery. It is therefore concluded that L in this newly established framework can discriminate between normal and proteoglycan-depleted cartilage samples. However, more samples will be needed to verify the demarcation between samples degraded for varying amount of time.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 81, May 2018, Pages 83-94
نویسندگان
, , , , , , , ,