کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7229975 1470930 2018 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Spatial-resolved dual-signal-output electrochemiluminescent ratiometric strategy for accurate and sensitive immunoassay
ترجمه فارسی عنوان
استراتژی ریاضی الکتروشیمیومیومسنتس دوتایی سیگنال خروجی فضایی برای سنجش ایمنی دقیق و حساس
کلمات کلیدی
تکنولوژی فضایی حل شده زاویه دید دوگانه سیگنال خروجی، دو سیگنال برچسب تشخیص دقیق با حساسیت بالا، آنتی ژن اختصاصی پروستات،
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
The identification of tumor markers is of great importance for clinical diagnosis but accurate detection with high sensitivity is still a great challenge. In present work, a spatial-resolved dual-signal-output electrochemiluminescent (ECL) ratiometric assay platform was constructed for sensitive detection of prostate specific antigen (PSA) on a dual-disk glassy carbon electrode. To fabricate the platform, flower-like CdS three-dimensional (3D) assemblies and Ru(bpy)32+-conjugated silica nanoparticles (Ru(bpy)32+@RuSi NPs), were immobilized onto the two disks as cathodic and anodic ECL emitters, respectively. After the stepwise modification of the gold nanoparticles, antibody for PSA, and bovine serum albumin onto the two disks respectively, the Ru(bpy)32+@RuSi NPs-based disk were incubated with varied concentration of PSA as working electrode, whereas the flower-like CdS 3D assemblies-based disk with fixed concentration of PSA were taken as internal reference electrode. The label free assay of PSA was realized by the ratio of anodic ECL signal from working electrode to the cathodic ECL signal from the internal reference electrode (ECLanode/ECLcathode). On the basis of the spatial-resolved dual-signal-output ratiometric ECL sensor, the PSA can be detected accurately with a linear range of 0.001 - 50 ng/mL at a concentration as low as 0.34 pg/mL. Furthermore, the proposed method was applied for PSA determination in human serum samples with satisfying results. Thanks to the same modified process of the two disks, this universal design well avoids environmental errors including the interference caused in the biological recognition process, which effectively reduces the false positive or negative errors, exhibiting a greatly improved accuracy, reliability and sensitivity.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 102, 15 April 2018, Pages 525-530
نویسندگان
, , , , ,