کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7230231 | 1470946 | 2016 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A sensitive electrochemiluminescent aptasensor based on perylene derivatives as a novel co-reaction accelerator for signal amplification
ترجمه فارسی عنوان
یک اپتاسنسور الکتروکمیلومینسسیته حساس با استفاده از مشتقات پرییلن به عنوان یک شتاب دهنده جدید واکنش برای تقویت سیگنال
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
Herein, a novel signal amplification strategy was designed using the perylene derivative as the co-reaction accelerator toward graphene-CdTe quantum dots (G-CdTe)/S2O82â system to construct a highly sensitive electrochemiluminescent (ECL) aptasensor for thrombin (TB) detection. Firstly, the G-CdTe nanocomposites were prepared by one-step method of in situ generating CdTe quantum dots onto the surface of the graphene oxide by using 3-mercaptopropionic acid as the CdTe QDs stabilizer. Then, a kind of perylene derivative (PTC-Lys), was synthesized by covalently binding L-lysine to 3,4,9,10-perylenetetracarboxylic acid, which was further immobilized onto the G-CdTe by the Ï-Ï* stacking and cross-linked the detection thrombin aptamer (TBA II) to obtain the TBA II/PTC-Lys/G-CdTe signal probes. It is worth pointing out that PTC-Lys acting as an efficient co-reaction accelerator interacted with the co-reactant of S2O82â rather than G-CdTe to promote the more oxidant mediators of SO4
- â, which could further react with G-CdTe to produce excited state species G-CdTe* for emitting light. Compared with the G-CdTe/S2O82â ECL system, our proposed strategy with the introduction of co-reaction accelerator of PTC-Lys exhibited ultra-high sensitivity to quantify the concentration of TB from 1.0Ã10â7Â nM to 10Â nM with a detection limit of 34Â aM.
- â, which could further react with G-CdTe to produce excited state species G-CdTe* for emitting light. Compared with the G-CdTe/S2O82â ECL system, our proposed strategy with the introduction of co-reaction accelerator of PTC-Lys exhibited ultra-high sensitivity to quantify the concentration of TB from 1.0Ã10â7Â nM to 10Â nM with a detection limit of 34Â aM.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 85, 15 November 2016, Pages 8-15
Journal: Biosensors and Bioelectronics - Volume 85, 15 November 2016, Pages 8-15
نویسندگان
Yan-Qing Yu, Hai-Yu Zhang, Ya-Qin Chai, Ruo Yuan, Ying Zhuo,