کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7230454 | 1470946 | 2016 | 23 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Conformation-sensitive antibody-based point-of-care immunosensor for serum Ca2+ using two-dimensional sequential binding reactions
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
To assess the homeostasis of Ca2+ metabolism, we have developed a rapid immunosensor for ionic calcium using a membrane chromatographic technique. As calcium-binding protein (CBP) is available for the recognition and undergone conformation change upon Ca2+ binding, a monoclonal antibody sensitive to the altered structure of CBP has been employed. The sequential binding scheme was mathematically simulated and shown to match with the experimental results. At the initial stage, the rapid analytical system using lateral flow was constructed by immobilizing the antibody on the immuno-strip nitrocellulose membrane and labeling CBP with colloidal gold as a tracer. A major problem with this system in measuring ionic calcium levels was retarded migration of the gold tracer along the immuno-strip. It was conceivable that the divalent cation at a high concentration caused a change in the physical properties of the tracer, resulting in a non-specific interaction with the membrane surface. This problem was circumvented by first eluting a sample containing biotinylated CBP along the immuno-strip and then supplying the gold coupled to streptavidin across the signal generation pad of the strip. The color signal was then generated via biotin-SA linkage and measured using a smartphone-based detector developed in our laboratory. This two-dimensional chromatographic format completed the Ca2+ analysis within 15Â min, the analytical performance covered the clinical dynamic range (0.25-2.5Â mM) and highly correlated with that of the reference system, i-STAT. These results inspired us to eventually investigate a dual-immunoassay system that measures simultaneously ionic calcium and parathyroid hormone, which regulates the ionic calcium level in serum. This will significantly simplify the current diagnostic protocols, which involve separate devices.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 85, 15 November 2016, Pages 611-617
Journal: Biosensors and Bioelectronics - Volume 85, 15 November 2016, Pages 611-617
نویسندگان
Ji-Na Park, Sung-Ho Paek, Dong-Hyung Kim, Sung-Min Seo, Guei-Sam Lim, Ju-Hee Kang, Sung-Pil Paek, Il-Hoon Cho, Se-Hwan Paek,