Polypyrrole based amperometric and potentiometric phosphate biosensors: A comparative study B
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The preparation of two electrochemical (potentiometric and amperometric) phosphate biosensors is described and compared. Purine nucleoside phosphorylase (PNP) and xanthine oxidase (XOD) were co-immobilized via entrapment into polypyrrole (PPy) films by galvanostatic polymerization. Polypyrrole entrapment was achieved with 0.5 M pyrrole by using a polymerization time of 200 s and a mole ratio of 1:8 (6.2 U/mL XOD: 49.6 U/mL PNP) in amperometric phosphate biosensor. Potentiometric bi-layer biosensor PPy-NO3/BSA-GLA-PNP-XOD is made of an inner electropolymerized PPy-NO3 layer and an outer layer of PNP and XOD cross-linked with a mixture of bovine serum albumen (BSA) and gultaraldehyde (GLA).The optimum conditions for potentiometric bi-layer biosensor include a polymerization time of 300 s for the inner layer at an applied current density of 0.25 mA cmâ2, a drying time of 30 min for the outer layer, pH 7, and 0.025 MTris-HCl. Sensitive amperometric measurements obtained from PPy-PNP-XOD-Fe(CN)64â biosensors were compared with those of potentiometric measurements obtained from PPy-NO3/BSA/GLA-PNP-XOD bi-layer biosensor. A minimum detectable concentration of 20.0 μM phosphates and a linear concentration range of 20-200 μM were achieved with potentiometric PPy-NO3/BSA/GLA-PNP-XOD biosensor. In comparison, a minimum detectable concentration of 10 μM and a linear concentration range of 0.1-1 mM were achieved with amperometric biosensor. The presence of uric and ascorbic acids had the least effect on the performance of the PPy-PNP-XOD-Fe(CN)64â amperometric and PPy-NO3/BSA/GLA-PNP-XOD potentiometric bi-biosensors, therefore, they will not have any effect on phosphate measurement in both biosensors at levels normally present in water. PPy-NO3/BSA-GLA-PNP-XOD potentiometric biosensor was used to analyse phosphate in real samples.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 40, Issue 1, 15 February 2013, Pages 377-384
Journal: Biosensors and Bioelectronics - Volume 40, Issue 1, 15 February 2013, Pages 377-384
نویسندگان
Abdulazeez T. Lawal, Samuel B. Adeloju,