کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
730823 893002 2006 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Tests on various configurations of Coriolis mass flowmeters
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
پیش نمایش صفحه اول مقاله
Tests on various configurations of Coriolis mass flowmeters
چکیده انگلیسی

Experiments have been conducted on various configurations of Coriolis mass flowmeters, such as U-tube, S-tube, L-tube, and stair shaped tubes, with water as the working fluid. The sensitivity of the flowmeter has been measured for a wide range of parameters like position of sensors, geometry, material properties, etc. The results of this study indicate that the measured phase shift is proportional to the mass flow rate. The slope ratio (theoretical to measured) is observed to be constant for the range of parameters studies for U-tube flowmeters. Sensor positions for maximum sensitivity have been identified for S-tube and L-tube configurations.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 39, Issue 4, May 2006, Pages 296–307