کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
740771 894186 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of volatile alcohols in apple juices by an electrochemical biosensor measuring in the headspace above the liquid
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Analysis of volatile alcohols in apple juices by an electrochemical biosensor measuring in the headspace above the liquid
چکیده انگلیسی

An electrochemical biosensor was optimised for the analysis of volatile alcohols directly from the gas phase without prior absorption or pre-concentration. The sensor is based on the alcohol oxidase (Pichia pastoris) catalyzed conversion of ethanol and the amperometric detection of the generated hydrogen peroxide. Key part of the three-electrode set-up was a gas-diffusion working electrode (potential: +600 mV vs. Ag/AgCl) that consisted of a porous Teflon membrane coated with a thin platinum layer. Headspace samples were analysed for alcohols and used to derive alcohol concentrations in the liquid phase. The biosensor had a sensitivity of 3.43 μA/mM for ethanol, a response time of 69 s, a linear dynamic range of 0.10–30 mM, a theoretical detection limit (3 < S/N) of 9.9 μM, and a stability of 86% during continuous operation (18 h @ 1 mM ethanol). Using one sensor on three consecutive days, the mean coefficient of variation was 1.3% (three measurements each day @ 10 mM ethanol). Alcohol contents of three apple juices determined with the biosensor were in the range 0.30 g/l–0.67 g/l (equivalent to 6.51 mM–14.5 mM). However, ethanol contents determined by high pressure liquid chromatography coupled to refractive index detection (HPLC-RI) and by a commercial enzyme test kit based on alcohol dehydrogenase ranged from 0.12 g/l to 0.38 g/l (equivalent to 2.60 mM–8.25 mM). Both indicate that the biosensor detected alcohols other than ethanol in the apple juices. HPLC-RI coupled to the biosensor in a flow-through configuration demonstrated that the biosensor detected methanol concomitant to ethanol. Thus, the biosensor could perform a qualitative analysis of the total content of volatile alcohols in apple juices by analysing the gas phase above the sample. This offers the additional advantage that possible, non-volatile interfering substances in the liquid sample cannot impair the measurement.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 158, Issue 1, 15 November 2011, Pages 313–318
نویسندگان
, , , ,