کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7616126 | 1494033 | 2016 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Simultaneous quantification of 2â²,3â²,5â²-tri-O-acetyl-N6-(3-hydroxylaniline)adenosine and its principal metabolites in hamster blood by LC-MS/MS and its application in pharmacokinetics study
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
2â²,3â²,5â²-Tri-O-acetyl-N6-(3-hydroxylaniline)adenosine (IMM-H007, once called WS070117) is being developed as a novel anti-hyperlipidemia agent for its high efficacy and low toxicity. In this study, a sensitive and specific liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was established for the simultaneous quantification of IMM-H007 and its two major metabolites (3S,4R,5R)-2-(hydroxymethyl)-5-(6-((3-hydroxyphenyl)amino)-9H-purin-9-yl)tetrahdrofuran-3,4-diol (M1) and ((2R,3S,4R,5R)-3,4-dihydroxy-5-(6-((3-hydroxyphenyl)amino)-9H-purin-9-yl)tetrahydrofuran-2-yl)methyl dihydrogen phosphate (MP) in hamster blood. An analogue of IMM-H007, WS070119 was used as the internal standard. Blood samples were prepared by a simple protein precipitation with acetonitrile. The chromatographic separation was performed on a ReproSil-Pur 120C18 column (3 μm, 2 mm Ã 100 mm) with a gradient mobile phase of methanol/water containing 0.1% formic acid (v/v) in a flow rate of 0.2 mL/min. Detection was carried out on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) in positive ion selective reaction monitoring (SRM) mode. The monitored transitions were 486.2 â 228.1 for IMM-H007, 360.0 â 228.0 for M1, 440.0 â 228.0 for MP and 374.1 â 242.0 for the internal standard, respectively. Satisfactory linearity was obtained for the analytes over the range of 1-500 ng/mL for IMM-H007, 2-1000 ng/mL for M1 and 10-5000 ng/mL for MP. The lower limits of the quantification (LLOQs) were 1 ng/mL for IMM-H007, 2 ng/mL for M1 and 10 ng/mL for MP. The intra-day and inter-day precisions (RSD, %) of the analytes were within 14.2%, and the accuracy (RE, %) ranged from â9.4% to 10.7%. The average recoveries of the analytes were more than 80.0%. The analytes were proved to be stable during given storage, preparation, and analytic procedures. The method was successfully applied to the pharmacokinetic study in hamsters after oral administration of IMM-H007.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 1022, 1 June 2016, Pages 46-53
Journal: Journal of Chromatography B - Volume 1022, 1 June 2016, Pages 46-53
نویسندگان
Yufei Jia, Baolian Wang, Xiangmeng Wu, Sheng Li, Jinping Hu, Dongmei Wang, Haibo Zhu, Yan Li,