کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7618357 | 1494106 | 2013 | 7 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Determination of nitrite and nitrate in cerebrospinal fluid by microchip electrophoresis with microsolid phase extraction pre-treatment
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
HDFMCEIsotachophoresisMSPEMHECMicrochip electrophoresis - الکتروفورز MicrochipHydrodynamic flow - جریان هیدرودینامیکیCerebrospinal fluid - مایع مغزی نخاعیCSF - مایع مغزی نخاعیNitrite and nitrate - نیتریت و نیتراتITP - و غیره.PMMA - پلی (متیل متاکریلات) Poly(methylmethacrylate) - پلی (متیل متاکریلات)Coupled channels - کانال های همراه
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
A new method for the determination of nitrite and nitrate, indicators of various neurological diseases (meningitis, multiple sclerosis, Parkinson's disease) in cerebrospinal fluid (CSF) on an electrophoresis chip was developed. An on-line combination of isotachophoresis (ITP) with capillary electrophoresis (CE) on a poly(methylmethacrylate) chip assembled with coupled separation channels (CC) and contact conductivity detectors was employed. ITP separations performed at low pH (3.6) in the first separation channel enabled a highly selective transfer of the analytes to the second CE stage working under micellar conditions implemented by zwitterionic surfactant, 3-(N,N-dimethyldodecylammonio)-propanesulfonate. The proposed method achieved low limits of detection varied from 0.2 to 0.4 μg Lâ1 when the sample volume injected onto the chip (9.9 μl) was almost the same as the volume of both separation channels. Preferable working conditions on the CC chip (suppressed hydrodynamic and electroosmotic flow) contributed for reproducible migration velocities (intra-day reproducibility up to 2.1% RSD) and determinations of trace concentrations of nitrite and nitrate (intra-day precision up to 3.0% RSD). Huge amount of chloride present in CSF (approx. 4.5 g Lâ1) was removed from analyzed CSF samples by microsolid phase extraction performed on silver-form resin prior to the ITP-CE analysis. Developed method provided fast (approx. 20 min total analysis time) and reliable determinations of trace nitrite and nitrate and could be fully integrated into the analysis of CSF samples.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 930, 1 July 2013, Pages 41-47
Journal: Journal of Chromatography B - Volume 930, 1 July 2013, Pages 41-47
نویسندگان
Peter TroÅ¡ka, Richard Chudoba, Ladislav DanÄ, Róbert Bodor, Michal HorÄiÄiak, Eva TesaÅová, Marián Masár,