کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8111412 | 1522294 | 2018 | 16 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A comprehensive review on the exergy analysis of combined cycle power plants
ترجمه فارسی عنوان
یک بررسی جامع در خصوص تحلیل اگزرژی نیروگاه های ترکیبی
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
BFPBFWHRSGCCPPHHVEVAECOLHVH2O - H2OCEP - MOBILEWater - آبBoiler feed water - آب تغذیه بویلرeconomizer - اقتصادزاEnergy - انرژیExergy - اکسرژیOxygen - اکسیژنReheater - بخاری برقیevaporator - تبخیرکننده، اواپراتورExergy destruction - تخریب اگزرژیSteam turbine - توربین بخارGas turbine - توربین گازDesuperheater - دیگ بخارCarbon dioxide - دیاکسید کربنSuperheater - سوپر بخارHigh pressure - فشار بالاIntermediate pressure - فشار متوسطLow pressure - فشار کمCombustion chamber - محفظه احتراقLow heating value - مقدار گرما کمHeat recovery steam generator - مولد بخار با توان بازیافت حرارتNitrogen - نیتروژنCombined cycle power plant - نیروگاه چرخه ترکیبیCO2 - کربن دیاکسیدHigh heating value - گرمای زیاد
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
The arriving optimum improvement of a thermodynamic system of energy conversion such as a combined cycle power plant (CCPP) is complicated due to the existence of different factors. Energy and exergy analysis is utilized as effective methods to determine both the quantity and quality of the energy sources. This paper reviews the latest thermodynamics analysis on each system components of a CCPP independently and determine the exergy destruction of the plant. A few layouts of the CCPP plant from different locations considered as case studies. In fact, the most energy losses occurred in the condenser compared with the plant components. It found that in the combustion chamber (CC) the highest exergy destruction occurred. The ambient temperature causes an evident decrement in the power production by the gas turbine (GT). The result has proved that besides energy, exergy analysis is an efficient way to the assessment of the performance of the CCPP by recommending a more advantageous configuration of the CCPP plant, which would lead to reductions in fuel required and emissions of air pollutants.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Renewable and Sustainable Energy Reviews - Volume 90, July 2018, Pages 835-850
Journal: Renewable and Sustainable Energy Reviews - Volume 90, July 2018, Pages 835-850
نویسندگان
Thamir K. Ibrahim, Mohammed Kamil Mohammed, Omar I. Awad, Ahmed N. Abdalla, Firdaus Basrawi, Marwah N. Mohammed, G. Najafi, Rizalman Mamat,