کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8251062 | 1533472 | 2018 | 30 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A comprehensive study on usage of Gd2O3 dielectric in MOS based radiation sensors considering frequency dependent radiation response
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
تشعشع
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: A comprehensive study on usage of Gd2O3 dielectric in MOS based radiation sensors considering frequency dependent radiation response A comprehensive study on usage of Gd2O3 dielectric in MOS based radiation sensors considering frequency dependent radiation response](/preview/png/8251062.png)
چکیده انگلیسی
The purpose of this study is to investigate the Gadolinium Oxide (Gd2O3) as a gate dielectric/sensitive region in MOS based radiation sensors and to provide a detailed description of the frequency-dependent gamma irradiation response of a Gd2O3 MOS capacitor. The 254â¯nm thick-Gd2O3 films were deposited on p-type Si wafers by using RF magnetron sputtering. The radiation response of the Gd2O3 MOS capacitors was investigated by 60Co irradiation in the range of 0.5-70â¯Gy. The capacitance-voltage (C-V) curves shifted to a more positive potential with increasing radiation dose due to there being more trapped electrons than holes. The variation in the oxide trap charge density was found to be in the range of ââ¯3.21â¯Ãâ¯1011 ±â¯1.57â¯Ãâ¯1010 cmâ2 - ââ¯1.70â¯Ãâ¯1012 ±â¯8.33â¯Ãâ¯1010 cmâ2 at 100â¯kHz and ââ¯2.26â¯Ãâ¯1011 ±â¯1.02â¯Ãâ¯1010 cmâ2 - ââ¯1.30â¯Ãâ¯1012 ±â¯6.02â¯Ãâ¯1010 cmâ2 (70â¯Gy) at 1â¯MHz. The maximum variation in the interface trap charge density was in order of 1011 cmâ2 at 1â¯MHz. The results indicate that the contribution of the oxide trap charge to radiation response of the Gd2O3 MOS capacitor is higher than that of the interface trap charges. The radiation sensitivities of the Gd2O3 MOS capacitor for 100â¯kHz and 1â¯MHz were determined as 59.2â¯Â±â¯2.9â¯mV/Gy and 62.7â¯Â±â¯2.9â¯mV/Gy, respectively. The percentage fading values (dose storage capability) measured in the time range of 25-145â¯min for 100â¯kHz varied from 2.2% to 11.4%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Physics and Chemistry - Volume 152, November 2018, Pages 36-42
Journal: Radiation Physics and Chemistry - Volume 152, November 2018, Pages 36-42
نویسندگان
A. Kahraman, E. Yilmaz,