کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8340929 | 1541267 | 2018 | 25 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Reproducibility and agreement of different non-invasive methods of endothelial function assessment
ترجمه فارسی عنوان
تکرارپذیری و توافق روشهای مختلف غیر تهاجمی ارزیابی عملکرد اندوتلیال
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
دیلاتاسیون متصل به جریان، حرارتی محلی حرارتی، فشارخون واکنشی پس از انسداد، اکسید نیتریک،
موضوعات مرتبط
علوم زیستی و بیوفناوری
بیوشیمی، ژنتیک و زیست شناسی مولکولی
زیست شیمی
چکیده انگلیسی
Flow-mediated dilatation (FMD) is an established, but investigator-demanding method, used to non-invasively determine nitric oxide (NO)-dependent endothelial function in humans. Local thermal hyperemia (LTH) or post-occlusive reactive hyperemia (PORH) of the skin measured with a laser Doppler flow imager may be a less demanding alternative of FMD. We investigated the reproducibility of the different measures of vascular function, their interrelationship and the NO-dependency of LTH. Measurements were performed twice in 27 healthy men (8 smokers), one week apart. Local application of NG-monomethyl-l-arginine (L-NMMA) by means of iontophoresis was used to determine the NO-dependency of LTH. Using L-NMMA, the peak and plateau responses of LTH were reduced by 31% (pâ¯<â¯.001) and 65% (<0.001), respectively. For all measurements the coefficient of variation (CV) was higher in smokers than in non-smokers. For non-smokers the CV of FMD was 12%, of LTH peak response 17%, of LTH plateau response 12%, of PORH peak response 14% and of PORH area under the curve response 11%. FMD correlated weakly with the PORH peak and area under the curve response (râ¯=â¯0.39 and 0.43, pâ¯<â¯.05), whereas the LTH-plateau response correlated with the PORH peak response (râ¯=â¯0.68, pâ¯<â¯.01) in non-smokers, but FMD and LTH peak or plateau responses were unrelated. In conclusion, the LTH plateau response is for two-third NO-dependent, but unrelated to FMD. Furthermore, despite easy to perform the LTH responses are not more reproducible than FMD. Given the weak associations, the different methods of vascular function assessment are not interchangeable.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microvascular Research - Volume 117, May 2018, Pages 50-56
Journal: Microvascular Research - Volume 117, May 2018, Pages 50-56
نویسندگان
Khatera Ibrahimi, Young De Graaf, Richard Draijer, A.H. Jan Danser, Antoinette Maassen VanDenBrink, Anton H. van den Meiracker,