کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8420313 | 1545893 | 2018 | 6 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A semi-continuous system for monitoring microbially influenced corrosion
ترجمه فارسی عنوان
سیستم نیمه مداوم برای نظارت بر خوردگی میکروبی تحت تاثیر قرار می گیرد
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم زیستی و بیوفناوری
بیوشیمی، ژنتیک و زیست شناسی مولکولی
بیوتکنولوژی یا زیستفناوری
چکیده انگلیسی
Microbially influenced corrosion (MIC), also known as biocorrosion, has significant impacts on the environment and economy. Typical systems to study biocorrosion are either dynamic (once-through flow) or static (serum bottle incubations). Dynamic systems can be materials and personnel intensive, while static systems quickly become nutrient limiting and exhibit long incubations. A semi-continuous biocorrosion cell was developed to address these issues. Low carbon shim steel was used as a test surface. Initial results revealed that 50â¯ppm glutaraldehyde (GLT), a common oil field biocide, in an abiotic cell was 3.6 times more corrosive (24.5â¯Ãâ¯10â3â¯mm/y) than a biocorrosion cell inoculated with a sulfate-reducing bacteria (SRB) enrichment (6.73â¯Ãâ¯10â3â¯mm/y). The SRB inoculated cell treated with GLT (50â¯ppm) reduced the corrosion rate from 6.73â¯Ãâ¯10â3â¯mm/y to 3.68â¯Ãâ¯10â3â¯mm/y. It was hypothesized that a biocide-surfactant combination would enhance biocide activity, thereby lowering corrosion in a semi-continuous biocorrosion cell. The biocide and surfactant were GLT (30â¯ppm) and Tween 80 (TW80; 100â¯ppm). MIC of SRB increased in the presence of a non-inhibitory concentration of GLT (23.4â¯Ãâ¯10â3â¯mm/y), compared to the untreated +SRB condition (8.29â¯Ãâ¯10â3â¯mm/y). The non-ionic surfactant alone reduced MIC (4.57â¯Ãâ¯10â3â¯mm/y) and even more so in combination with GLT (3.69â¯Ãâ¯10â3â¯mm/y). Over 50% of 16S rDNA sequences in the biofilm on the test surface were identified as belonging to the genera Desulfovibrio and Desulfomicrobium. The utility of a semi-continuous system for MIC studies and biocide testing was demonstrated. The concept of regular partial medium replacement is applicable to different corrosion cell and corrosion coupon geometries. Biocide-surfactant combinations may have the potential to reduce the concentration of biocides used in the field. In addition, a semi-defined medium for enumerating Acid-Producing Bacteria (APB) was developed, resulting in higher recoveries compared to a standard phenol red medium (e.g., 1.1â¯Ãâ¯104 APB/cm2 vsâ¯<â¯4â¯Ãâ¯10â1 APB/cm2).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Microbiological Methods - Volume 150, July 2018, Pages 55-60
Journal: Journal of Microbiological Methods - Volume 150, July 2018, Pages 55-60
نویسندگان
Mary M. Eid, Kathleen E. Duncan, Ralph S. Tanner,