کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8501443 1553842 2018 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Short communication: Evaluation of 5 different ELISA for the detection of bovine leukemia virus antibodies
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم دامی و جانورشناسی
پیش نمایش صفحه اول مقاله
Short communication: Evaluation of 5 different ELISA for the detection of bovine leukemia virus antibodies
چکیده انگلیسی
Although Canadian dairy herds have been infected with bovine leukemia virus (BLV) for years, recent research has put new emphasis on the potential negative effects of this infection. Consequently, BLV control is becoming more favorable; however, BLV control cannot be successful without identifying infected animals. Bovicheck BLV (Biovet, Saint-Hyacinthe, QC, Canada) is currently the only assay licensed by the Canadian Centre for Veterinary Biologics. The first goal of this study was, therefore, to determine the reproducibility of the Bovicheck BLV assay for serum samples derived from Canadian cattle. The second goal was to evaluate and compare 5 different ELISA and determine their test characteristics using serum samples from Canadian herds. The considered ELISA were Bovicheck BLV, ID Screen BLV Competition (IDvet, Grabels, France), Idexx Leukosis Serum X2 Ab Test (Idexx Europe B.V., Hoofddorp, the Netherlands), Svanovir BLV gp51-Ab (Svanova, Uppsala, Sweden), and the Serelisa BLV Ab Mono Indirect (Synbiotics, Lyon, France). Eighty serum samples from Canadian cattle provided by Prairie Diagnostic Services (PDS; Saskatoon, SK, Canada) and an additional 80 serum samples from Canadian dairy and beef herds were used for the study. The Bovicheck BLV assay yielded the same results for all PDS-derived samples, implying a high level of reproducibility and robustness of this assay. Additionally, the comparison of the assays' results showed high agreement between assays, with Cohen's kappa values between κ = 0.91 and κ = 1. Furthermore, using original test results of the field samples as true status, relative diagnostic sensitivity and specificity were calculated. Relative diagnostic sensitivity of all tests was 100%. False-positive results were probable; therefore, the following relative diagnostic specificities were determined: 100% for Bovicheck BLV, Idexx Leukosis Serum X2, and Svanovir BLV; 95% for ID Screen BLV; and 97% for Serelisa BLV. When considering other test characteristics, ID Screen BLV is exceptional due to considerable practical advantages.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Dairy Science - Volume 101, Issue 3, March 2018, Pages 2433-2437
نویسندگان
, , , , , ,