کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
866714 1470978 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparative label-free monitoring of immunotoxin efficacy in 2D and 3D mamma carcinoma in vitro models by impedance spectroscopy
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Comparative label-free monitoring of immunotoxin efficacy in 2D and 3D mamma carcinoma in vitro models by impedance spectroscopy
چکیده انگلیسی


• We established a label-free impedimetric monitoring for 2D and 3D cultures
• We demonstrated the efficacy monitoring on a novel polyionic immunotoxin
• We compared the immunotoxin efficacy to the small molecule drug paclitaxel
• Viability and proliferation analysis validated the impedimetric analysis

For selective killing of tumor cells, there are many novel and promising therapeutic approaches like immunotoxins. However, on the long way to clinical application, especially in vitro approved biologicals often fail due to loss of target sensitivity and efficacy in vivo. This is mostly explained with degradation or penetration disability in vivo. Although, these problems are well known, until today, there are no in vitro systems for reliable monitoring and quantification of therapeutic efficacy in 3D tumor models and the direct comparison to results from 2D models. In this context, we developed a combined label-free impedimetric monitoring system using our self-developed planar interdigital electrode arrays and our unique microcavity array technology. Therefore, we could demonstrate the time and concentration dependent monitoring and quantification of therapeutic efficacy in a 2D and 3D mamma carcinoma model. In detail, we synthesized a novel modular immunotoxin B3(dsFv)-PE38 (B3-PE38) in which the antibody fragment and the protein toxin are polyionic linked together. We compared the efficacy of the immunotoxin B3-PE38, the toxin E8C-PE38 (PE38) and the small molecule chemotherapeutic paclitaxel. The impedimetric screening revealed the highest cytotoxicity for the immunotoxin B3-PE38 in the 2D model. More strikingly, the immunotoxin efficacy was substantially higher in the 3D model when compared to PE38 and paclitaxel even though having a considerably lower penetration capability than paclitaxel. So our novel impedimetric monitoring system offers the comparative efficacy quantification of novel therapeutics in 2D and 3D in vitro tumor models.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 53, 15 March 2014, Pages 370–376
نویسندگان
, , , , , ,