کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
866726 1470978 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Competitive-type displacement reaction for direct potentiometric detection of low-abundance protein
ترجمه فارسی عنوان
واکنش جابجایی نوع رقابتی برای تشخیص پتانسیومتری مستقیم پروتئین کم فراوانی
کلمات کلیدی
واکنش جابجایی نوع رقابتی، آنتیبادی حاوی نانوذرات، آنتی ژن اختصاصی پروستات، ایمنی سنجی پتانسیومتریک، پلی اتیلنیمین پلی (استایرن اکریلیک اسید) میکروسفور
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• We introduced a new homogeneous immunoassay for detection of low-abundance protein.
• Competitive-type displacement reaction was utilized during the measurement.
• The assay was carried out on an electrostatic reaction-based sensing platform.

Prostate-specific antigen (PSA), one of the indications of possible prostate malignancy, is used as a biomarker for the diagnosis and prognosis of prostate cancer. Herein, we develop a new homogeneous potentiometric immunoassay for sensitive detection of low-concentration PSA without the need of sample separation and washing step. Two nanostructures including positively charged polyethyleneimine-poly(styrene-co-acrylic acid) (PEI-PSAA) nanospheres and negatively charged gold nanoparticles conjugated with anti-PSA antibody (Ab-AuNP) were first synthesized by using mulsifier-free emulsion copolymerization and wet chemistry method, respectively. Thereafter, the as-prepared PEI-PSAA was used as a pseudo hapten for the construction of immunosensing probe based on an electrostatic interaction between PEI-PSAA and Ab-AuNP. Upon target introduction, the added PSA competed with PEI-PASS for Ab-AuNP based on a specific antigen–antibody interaction, and displaced Ab-AuNP from PEI-PASS. The dissociated PEI-PASS was captured through the negatively charged Nafion- modified electrode, thereby resulting in the change of membrane potential. The fabrication process was characterized by using high-resolution transmission electron microscope (HRTEM), scanning electron microscope with energy-dispersive X-ray spectroscopy (SEM-EDX), surface plasmon resonance (SPR) and dynamic laser scattering (DLS) technique. Under optimal conditions, the output signal was indirectly proportional to the concentration of target PSA in the sample and exhibited a dynamic range from 0.1 to 50 ng/mL with a detection limit (LOD) of 0.04 ng/mL. Intra- and inter-assay coefficients of variation (CVs) were 6.8 and 7.5%, respectively. In addition, the methodology was evaluated for analysis of 12 clinical serum samples and showed good accordance between the results obtained by the developed immunosensing protocol and a commercialized enzyme-linked immunosorbent assay (ELISA) method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 53, 15 March 2014, Pages 465–471
نویسندگان
, , , ,