کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
866843 1470988 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
rGO/SWCNT composites as novel electrode materials for electrochemical biosensing
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
rGO/SWCNT composites as novel electrode materials for electrochemical biosensing
چکیده انگلیسی

In this study we performed electrochemical sensing using conductive carbon composite films containing reduced graphene oxide (rGO) and single-walled carbon nanotubes (SWCNTs) as electrode modifiers on glassy carbon electrodes (GCEs). Raman spectroscopy, transmission electron microscopy, atomic force microscopy, and scanning electron microscopy all suggested that the rGO acted as a surfactant, covering and smoothing out the surface, and that the SWCNTs acted as a conducting bridge to connect the isolated rGO sheets, thereby (i) minimizing the barrier for charge transfer between the rGO sheets and (ii) increasing the conductivity of the film. We used the rGO/SWCNT–modified GCE as a sensor to analyze hydrogen peroxide (H2O2) and β-nicotinamide adenine dinucleotide (NADH), obtaining substantial improvements in electrochemical reactivity and detection limits relative to those obtained from rGO- and SWCNT-modified electrodes, presumably because of the higher conductivity and greater coverage on the GCE, due to π–π interactions originating from the graphitic structures of the rGO and SWCNTs. The electrocatalysis response was measured by cyclic voltammetry and amperometric current–time (i–t) curve techniques. The linear concentration range of H2O2 and NADH detection at rGO/SWCNT–modified electrode is 0.5–5 M and 20–400 μM. The sensitivity for H2O2 and NADH detection is 2732.4 and 204 μA mM−1 cm−2, and the limit of detection is 1.3 and 0.078 μM respectively. Furthermore, interference tests indicated that the carbon composite film exhibited high selectivity toward H2O2 and NADH. Using GO as a solubilizing agent for SWCNTs establishes a new class of carbon electrodes for electrochemical sensors.


► A novel method used the rGO/SWCNT composite for electrode modifier.
► The modified electrode has high sensitivity and low detection limit toward analyte.
► Interference test indicated carbon composite film showing the high selectivity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 43, 15 May 2013, Pages 173–179
نویسندگان
, , , , ,