کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
868876 909815 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose
چکیده انگلیسی

The highly sensitive urine glucose meter based on amperometric glucose sensor was developed and commercialized. It shows remarkable performances of wide measurement range in 0–2000 mg dl−1, rapid response time as 6 s and robustness against influence by interferents like ascorbic acid or acetaminophen. Correlation between the developed urine glucose meter and commercialized clinical-use urine glucose analyzer showed excellent linear relationship. The monitoring of postmeal blood glucose levels by assess of urine glucose of actual subjects was performed with the developed urine glucose meter. The experimental results suggest the urine glucose level 120 min following the meal should be the appropriate index for diabetes or impaired glucose tolerance to control blood glucose level. The new portable meter was developed, and is expected for flexible use at places other than home or office.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 24, Issue 5, 1 January 2009, Pages 1336–1340