کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
875742 910799 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Precision of image-based registration for intraoperative navigation in the presence of metal artifacts: Application to corrective osteotomy surgery
ترجمه فارسی عنوان
دقت ثبت نام مبتنی بر تصویر برای ناوبری درون عمل در حضور مصنوعات فلزی: کاربرد در عمل جراحی استئوتومی اصلاح
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
چکیده انگلیسی


• We focus on the precision of intraoperative 3-D based patient-to-image registration for corrective osteotomy surgery.
• We investigate registration precision with and without metal artifact reduction applied before registration, and with and without user intervention during the registration procedure.
• Registration precision with user intervention is much higher than without user intervention.
• In the specific application the precision of registration with metal artifact reduction is not significantly different.

Navigation for corrective osteotomy surgery requires patient-to-image registration. When registration is based on intraoperative 3-D cone-beam CT (CBCT) imaging, metal landmarks may be used that deteriorate image quality. This study investigates whether metal artifacts influence the precision of image-to-patient registration, either with or without intermediate user intervention during the registration procedure, in an application for corrective osteotomy of the distal radius. A series of 3-D CBCT scans is made of a cadaver arm with and without metal landmarks. Metal artifact reduction (MAR) based on inpainting techniques is used to improve 3-D CBCT images hampered by metal artifacts. This provides three sets of images (with metal, with MAR, and without metal), which enable investigating the differences in precision of intraoperative registration. Gray-level based point-to-image registration showed a better correlation coefficient if intraoperative images with MAR are used, indicating a better image similarity. The precision of registration without intermediate user intervention during the registration procedure, expressed as the residual angulation and displacement error after repetitive registration was very low and showed no improvement when MAR was used. By adding intermediate user intervention to the registration procedure however, precision was very high but was not affected by the presence of metal artifacts in the specific application.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Engineering & Physics - Volume 37, Issue 6, June 2015, Pages 524–530