کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
876106 910825 2012 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six different state-of-the-art meshes
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
پیش نمایش صفحه اول مقاله
Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six different state-of-the-art meshes
چکیده انگلیسی

BackgroundAn ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model.MethodsNew Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix® L/P, Gore Dualmesh®, Bard Sepramesh®, Ethicon Proceed® or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal walls with ingrown meshes were harvested and examined biomechanically with a plunger test. The mesh–tissue compliance was evaluated by the forces exerted at given displacements and also described through a simple mathematical approximation. Abdominal wall samples were collected for histopathology, cell turnover and morphometry.ResultsNo mesh-related complications were seen. The adhesion score was significantly higher in Bard Composix® L/P and Ethicon Proceed® meshes. Significant shrinkage was seen in Gore Dualmesh® and Parietex™ Composite meshes. Physiomesh™ exhibited the highest compliance during plunger testing, characterized by lower, more physiological reaction forces against tissue displacement than the competitor meshes. In contrast, the safety modulus was comparable in all groups. Histology showed less collagen and less foreign body reaction in the Physiomesh™ samples contributing to patient's comfort.ConclusionIn terms of safety, this study showed no superiority of any single mesh. The comfort modulus however differed, being lowest in the newly developed Physiomesh™.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Engineering & Physics - Volume 34, Issue 7, September 2012, Pages 806–816
نویسندگان
, , , , ,