کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8866610 1621190 2018 19 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The impacts of spatial baseline on forest canopy height model and digital terrain model retrieval using P-band PolInSAR data
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات کامپیوتر در علوم زمین
پیش نمایش صفحه اول مقاله
The impacts of spatial baseline on forest canopy height model and digital terrain model retrieval using P-band PolInSAR data
چکیده انگلیسی
Polarimetric Synthetic Aperture Radar Interferometry (PolInSAR) has shown potential for the retrieval of a forest canopy height model (CHM) and the underlying solid earth digital terrain model (DTM). However, because of non-volume decorrelation and other unavoidable errors, the robustness of retrieval heights is sensitive to the spatial baseline of the selected InSAR pairs, which relates forest parameters to measured coherence. Within the context of the random volume over ground (RVoG) model and the three-stage inversion method, we aimed to quantify the influence of spatial baseline on the inversions at P-band, which are distinct from the inversions at higher frequency due to the non-negligible ground contributions. This information assists in optimal baseline selection and the development of robust inversion schemes. Assumptions about the extinction coefficient and additional DTM or DEM were used to reduce the influence of ground contribution on CHM and DTM inversion, respectively. Inversions from published airborne repeat-pass P-band PolInSAR data with four different spatial baselines were validated against LiDAR-derived DTM and CHM data. The results show that a longer spatial baseline performed better in DTM inversion. The longest baseline produced the best R2 of 0.995 and RMSE of 0.555 m, much better than the smallest baseline with an R2 of 0.794 and RMSE of 3.74 m. A threshold height could be identified that determines the overestimation and underestimation of CHM inversion due to the non-volume decorrelation. Different baselines produced different threshold heights, making CHM inversion only accurate for a limited range of forest height around the threshold. The optimal baseline produced a CHM with R2 of 0.605 and RMSE of 2.67 m. Additionally, we found that using multiple baselines has the potential to improve CHM inversion, improving the R2 to 0.827 and RMSE to 0.876 m in our study.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Remote Sensing of Environment - Volume 210, 1 June 2018, Pages 403-421
نویسندگان
, , , , ,