کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
96866 | 160474 | 2011 | 8 صفحه PDF | دانلود رایگان |

Skin is a less than ideal medium for recording bitemark impressions, and assessing the causes and magnitude of distortion has long been a question in forensic odontology. Affine methods have been suggested as a mathematical means to attempt to quantify the deformation typically seen with a bitemark. Thirty-six bites were created on unembalmed human cadavers with a single dentition. Three mathematical affine methods were evaluated to determine if the distortion could be described mathematically and effectively removed. A measure of mismatch of a dentition to a bitemark was developed based on landmark measurements establishing a numerical basis for comparisons of dentitions to bitemarks. Results indicate high levels of distortion in the bitemarks not attributable to affine deformations or measurement error, suggesting that non-uniform anisotropic properties of skin mostly contribute to the distortion seen, thus concluding that bitemark distortion cannot be corrected by using affine transformations.
Journal: Forensic Science International - Volume 207, Issues 1–3, 15 April 2011, Pages 111–118