کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9753263 1494198 2005 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of metformin in human plasma by high-performance liquid chromatography
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of metformin in human plasma by high-performance liquid chromatography
چکیده انگلیسی
A simple, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of antihyperglycemic agent metformin in human plasma using a novel sample extraction procedure. Liquid-liquid extraction of metformin and ranitidine (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (50:50, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a silica column (250 mm × 4.6 mm, 5 μm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (25:75, v/v), pH 6. The limit of quantification (LOQ) was 15.6 ng/ml and the calibration curves were linear up to 2000 ng/ml. The mean absolute recoveries for metformin and internal standard using the present extraction procedure were 98 and 95%, respectively. The intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 8.3%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 824, Issues 1–2, 25 September 2005, Pages 319-322