کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10416072 898183 2005 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Gas chromatography/mass spectroscopy for plastics failure analysis
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Gas chromatography/mass spectroscopy for plastics failure analysis
چکیده انگلیسی
Gas chromatography/mass spectroscopy is particularly useful as an analytical method for plastics failure analysis in cases where detection of an unknown contaminant or other compositional factor may be the cause or a contributor to failure. It takes advantage of the fact that GC is a method of separating compounds in a mixture, permitting their identification and possibly quantification. MS is not only a very sensitive detector but also gives mass spectra of GC peaks, permitting their identification in many cases. In thermal desorption GC/MS compounds are transferred from the sample to the GC with heat. Completely nonvolatile materials are not detected. Using desorption temperatures up to 300-350 °C, many components of plastics can be analyzed. In pyrolysis GC/MS the sample is decomposed at temperatures up to 900 °C; GC/MS analyzes the pyrolyzate. Examples are given of causes of plastics failures that have been determined by GC/MS.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 12, Issue 6, December 2005, Pages 851-859
نویسندگان
, ,