Developing a sequential injection-square wave voltammetry (SI-SWV) method for determination of atrazine using a hanging mercury drop electrode
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Developing a sequential injection-square wave voltammetry (SI-SWV) method for determination of atrazine using a hanging mercury drop electrode Developing a sequential injection-square wave voltammetry (SI-SWV) method for determination of atrazine using a hanging mercury drop electrode](/preview/png/10529558.png)
چکیده انگلیسی
This paper describes the development of a sequential injection analysis method to automate the determination of atrazine by square wave voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. To perform these tasks, an 800 μL monosegment is formed, composed by 400 μL of sample and 400 μL of buffer/standard solution. To obtain an efficient homogenization, the sample solution is divided in five zones intercalated by four zones of the Britton-Robinson buffer (pH 2.0) in presence of appropriate concentration of NaNO3 and varying atrazine standard concentrations. This mixture zone is isolated from the carrier solution by two 100 μL air bubbles. After homogenization in an auxiliary reaction coil the mixture zone is injected toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode, at a flow rate of 50 μL sâ1. After a suitable delay time, the potential is scanned from â0.5 to â1.2 V versus Ag/AgCl using a frequency of 300 Hz and pulse height of 25 mV. The linear dynamic range is observed for atrazine concentrations between 1.16 Ã 10â7 and 2.32 Ã 10â6 mol Lâ1, obeying the linear equation ip = (â6.91 ± 0.07) Ã 108[atrazine] + (4 ± 8), with r2 = 0.9996, for which the slope is given in nA L molâ1. The detection and quantification limits of the method are 2.1 Ã 10â8 and 7.0 Ã 10â8 mol Lâ1, respectively. The sampling frequency is 37 hâ1, when the standard addition protocol is followed. This frequency can be increased to 42 hâ1 if the protocol to obtain in-line calibration curve is used for quantification. The method was applied for determination of atrazine in spiked river water samples and its accuracy was evaluated by comparison with the batch standard addition approach, which revealed that there is no evidence of statistically significant differences between the two methods.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 528, Issue 1, 3 January 2005, Pages 21-27
Journal: Analytica Chimica Acta - Volume 528, Issue 1, 3 January 2005, Pages 21-27
نویسندگان
Luciana B.O. dos Santos, Marcelo S.P. Silva, Jorge C. Masini,