The highest sensitivity (limit of detection (LOD) of 0.4 μg Lâ1) was obtained with MAb 12 in the direct assay. However, the inhibition assay was the most robust and the PAbs showed the highest sensitivity (LOD of 0.5-1 μg Lâ1). The antibodies were specific for BVA and BPA as only minor cross-reactivities were found toward structurally related compounds or other endocrine disruptors. In the inhibition assay (with a run time of 6 min), water samples spiked with BPA at different levels (0.5-50 μg Lâ1) resulted in recoveries varying between 68% and 121%. The sensitivity of the inhibition assay could be improved 40 times (LOD of 0.03 μg Lâ1 with the Mab 12-based assay) using solid phase extraction (SPE).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 528, Issue 1, 3 January 2005, Pages 37-45
Journal: Analytica Chimica Acta - Volume 528, Issue 1, 3 January 2005, Pages 37-45
نویسندگان
Gerardo R. Marchesini, Eline Meulenberg, Willem Haasnoot, Hubertus Irth,