کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10550944 967097 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Stereoselective method development and validation for determination of concentrations of amphetamine-type stimulants and metabolites in human urine using a simultaneous extraction-chiral derivatization approach
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Stereoselective method development and validation for determination of concentrations of amphetamine-type stimulants and metabolites in human urine using a simultaneous extraction-chiral derivatization approach
چکیده انگلیسی
Amphetamine-type stimulants (ATS) are a group of chiral amine drugs which are commonly abused for their sympathomimetic and stimulant properties. ATS are extensively metabolised by hepatic cytochrome P450 enzymes. As metabolism of ATS has been shown to be highly stereospecific, stereoselective analytical methods are essential for the quantitative determination of ATS concentrations for both in vivo and in vitro studies of ATS metabolism. This paper describes a new stereoselective method for the simultaneous determination of amphetamine (AM), methamphetamine (MA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), 4-hydroxy-3-methoxymethamphetamine (HMMA), 4-hydroxy-3-methoxyamphetamine (HMA), 3,4-hydroxymethamphetamine (HHMA) and 3,4-hydroxyamphetamine (HHA) in human urine samples validated according to the United States Food and Drug Administration guidelines. In this method, analytes are simultaneously extracted and derivatized with R-(−)-α-methoxy-α-(trifluoromethyl)phenylacetyl chloride (R-MTPCl) as the chiral derivatization reagent. Following this, the analytes were subjected to a second derivatization with N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) which targets the hydroxyl groups present in HMMA, HMA, HHMA and HHA. The derivatized analytes were separated and quantified using gas chromatography-mass spectrometry (GC-MS). The method was evaluated according to the established guidelines for specificity, linearity, precision, accuracy, recovery and stability using a five-day protocol. Intra-day precision ranged from 0.89 to 11.23% RSD whereas inter-day precision was between 1.03 and 12.95% RSD. Accuracy values for the analytes ranged from −5.29% to 13.75%. Limits of quantitation were 10 μg/L for AM, MA, MDMA, HMA and HMMA and 2 μg/L for MDA, HMA and HHA. Recoveries and stability values were also within accepted values. The method was applied to authentic ATS-positive samples.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 879, Issue 1, 1 January 2011, Pages 8-16
نویسندگان
, , ,