چکیده انگلیسی
Three different electroanalytical techniques for the detection of manganese in marine sediments are evaluated. The anodic stripping voltammetry of manganese at an in situ bismuth-film-modified boron-doped diamond electrode and cathodic stripping voltammetry at a carbon paste electrode are shown to lack the required sensitivity and reproducibility whereas cathodic stripping voltammetry at a bare boron-doped diamond electrode is shown to be reliable and selective with a limit of detection, from applying a 60 s accumulation period of 7.4 × 10−7 M and a sensitivity of 0.24 A M−1. The method was used to evaluate the manganese content of marine sediments taken from Šibenik, Croatia.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 65, Issue 2, 30 January 2005, Pages 423-429