کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
10561590 | 969779 | 2005 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Extraction chromatographic method for the separation of actinides and lanthanides using EDHBA grafted AXAD-16 polymer
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
A new extraction chromatographic method has been developed by grafting chloromethylated polymer support with 4-ethoxy-N,N-dihexylbutanamide (EDHBA), for the selective extraction of U(VI), Th(IV), La(III) and Nd(III) from highly acidic matrices. The developed grafted polymer has been characterized using 13C-CPMAS NMR spectroscopy, FT-NIR spectroscopy and also by CHN elemental analysis. The water regaining capacity of the grafted polymer is studied by TGA measurements and the active participation of the amide moiety towards metal ion complexation has been confirmed by Far IR spectroscopy. For the quantitative extraction of metal ions to the resin phase, various physio-chemical parameters are optimized by both static and dynamic methods. The developed amide grafted polymeric matrix shows good distribution ratio values even at high acidities, with the maximum metal sorption capacity values being 0.36, 0.69, 0.32 and 0.42 mmol gâ1 for U(VI), Th(IV), La(III) and Nd(III), respectively, at 6 M HNO3 medium. The kinetics of metal ion phase equilibration is found to be moderately fast, with t1/2 values of <6 min, for all the analytes of interest. The limits of analyte quantification (LOQ) using the developed method are in the range of 15-30 μg Lâ1. Moreover, the sequential separation of the sorbed actinides and lanthanides could be achieved by first eluting with 100 mL of distilled water (for actinides) followed by elution with 20 mL of 0.1 M EDTA (for lanthanides). The selectivity behavior and the practical applicability of the developed resin are tested using synthetic low level nuclear reprocessing mixtures and also with monazite sand. The analytical data are within 3.8% relative standard deviation, reflecting the reproducibility and reliability of the developed method.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 65, Issue 3, 15 February 2005, Pages 735-742
Journal: Talanta - Volume 65, Issue 3, 15 February 2005, Pages 735-742
نویسندگان
M. Akhila Maheswari, M.S. Subramanian,