کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10691482 1019599 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Liver Stiffness Measurements by Means of Supersonic Shear Imaging in Patients Without Known Liver Pathology
ترجمه فارسی عنوان
اندازه گیری شدت کبد با استفاده از تصویربرداری برشی فوق العاده در بیماران بدون آسیب شناسی کبدی
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم آکوستیک و فرا صوت
چکیده انگلیسی
We used supersonic shear imaging to determine the liver stiffness (LS) values of 82 patients without known liver pathology and studied the factors that influence these measurements. Five LS measurements were made in each subject, and the median value, expressed in kilopascals, was calculated. Reliable LS measurements were obtained in 84.5% of patients. Higher body mass index and older age were associated with failure to obtain reliable measurements. The mean value of LS measurements determined by SSI in our cohort of patients without known liver pathology was 6 ± 1.4 kPa. The mean LS measurements determined by SSI for men were significantly higher than those for women; body mass index did not significantly influence SSI measurements. Thus, 6 kPa is the mean SSI value in patients without known liver pathology, with higher values being obtained in men.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasound in Medicine & Biology - Volume 39, Issue 8, August 2013, Pages 1362-1367
نویسندگان
, , , , , , ,