کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1162915 1490905 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry
ترجمه فارسی عنوان
یک روش بهبود یافته شبه هدفمند متابولومیسم با استفاده از نظارت چندگانه یون ها با لیست های یون زمان گسسته براساس کروماتوگرافی مایع با کارایی بالا و چهار بعدی طیف سنجی جرمی پرواز
کلمات کلیدی
متابولوموپی شبه هدفمند، مانیتورینگ چندگانه، فهرست یونهای زمان گسسته، آسیب کبدی ناشی از الکل
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• An UHPLC/Q-TOF tsMIM MS-based pseudotargeted metabolomics was proposed.
• Compared to full scan, the improved method exhibits better repeatability and a wider linear range.
• The proposed method could achieve pseudotargeted analysis on one UHPLC/Q-TOF/MS instrument.
• The developed method was successfully used to discover biomarkers for alcohol-induced liver injury.

Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 927, 13 July 2016, Pages 82–88
نویسندگان
, , , , , , ,