کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163199 1490934 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Porous membrane-protected molecularly imprinted polymer micro-solid-phase extraction for analysis of urinary cocaine and its metabolites using liquid chromatography – Tandem mass spectrometry
ترجمه فارسی عنوان
برای تجزیه و تحلیل کوکائین ادراری و متابولیت های آن با استفاده از کروماتوگرافی مایع، یک پروتئین مولکولی محافظت شده با غشای متخلخل محافظت می شود. طیف سنجی جرم دو طرفه
کلمات کلیدی
غشای متخلخل محافظت شده پلیمر مونوآموخته استخراج فاز میکرو جامد، ادرار انسان، کوکائین، طیف سنجی جرمی کروماتوگرافی با عملکرد بالا
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Molecularly imprinted polymer (MIP) for cocaine recognition in urine samples.
• μ-SPE device based on porous membrane-protected containing MIP.
• Fast cocaine and metabolites determination by reverse phase HPLC-MS/MS.
• Limit of quantification lower than the cut-off values for cocaine abuse confirmation.

Porous membrane-protected micro-solid phase extraction (μ-SPE) using a molecularly imprinted polymer (MIP) as an adsorbent has been proposed as an integrated extraction-cleanup procedure for isolating cocaine (COC) and its metabolites [benzoylecgonine (BZE), ecgonine methyl ester (EME), and cocaethylene (CE)] from human urine. MIP beads have been synthesized using COC as a template molecule, ethylene dimethacrylate (EDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2′-azobisisobutyronitrile (AIBN) as an initiator. High performance liquid chromatography – tandem mass spectrometry (HPLC-MS/MS) has been used for quantifying the analytes after MIP-μ-SPE. Variables such as urine pH, adsorption temperature and time, mechanical (orbital-horizontal) stirring; and composition of the eluting solution and eluting time, were evaluated. The proposed method was shown to be precise and accurate [relative standard deviations (RSDs) of intra- and inter-day tests ranging from 3 to 8% and from 2 to 10%, respectively]; and analytical recoveries in the range of 89–100%). In addition, excellent accuracy was also verified after analyzing a FDT +25% control material for BZE. The detection limits were in the range of 0.16–1.7 ng L−1, low enough for confirmative conclusions regarding cocaine abuse. The method was finally applied for screening/quantifying cocaine and metabolites in urine samples from poly-drug abusers.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 898, 22 October 2015, Pages 50–59
نویسندگان
, , , , ,