کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163412 1490941 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Preparation of poly(3,4-ethylenedioxythiophene) nanofibers modified pencil graphite electrode and investigation of over-oxidation conditions for the selective and sensitive determination of uric acid in body fluids
ترجمه فارسی عنوان
آماده سازی الکترودهای گرافیت مداد اصلاح شده پلی کربنات (3،4-اتیلن اکسیدیهوفن) و بررسی شرایط بیش از حد اکسیداسیون برای تعیین انتخاب و حساسیت اسید اوریک در مایعات بدن
کلمات کلیدی
اسید اوریک، اسید اسکوربیک، پلی (3،4-اتیلن دی سکتیفوفن)، بیش از حد اکسیداسیون، سرم خون، ادرار
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Modification of pencil graphite with over-oxidized PEDOT nanofibers was performed.
• The prepared electrodes were used in the voltammetric determination of uric acid.
• The over-oxidation potential and time has a prominent effect on the responses.
• A very high peak separation (463 mV) was obtained between ascorbic and uric acids.
• Analytical application of the electrodes was successfully tested in real samples.

In this study, we have performed the preparation of over-oxidized poly(3,4-ethylenedioxythiophene) nanofibers modified pencil graphite electrode (Ox-PEDOT-nf/PGE) to develop a selective and sensitive voltammetric uric acid (UA) sensor. It was noted that the over-oxidation potential and time had a prominent effect on the UA response of the Ox-PEDOT-nf/PGE. Characterizations of PEDOT-nf/PGE and Ox-PEDOT-nf/PGE have been performed by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The highest voltammetric response of UA was obtained at pH 2.0. A linear relationship between the concentration of UA and oxidation peak currents was observed in the concentration range of 0.01–20.0 μM. The detection limit (1.3 nM according to S/N = 3) and reproducibility (RSD: 4.6 % for N:10) have also been determined. The effects of different substances on the determination of UA have been investigated. A very high peak separation value of 423 mV was obtained between UA and ascorbic acid which is the major interfering substance for UA. The use of Ox-PEDOT-nf/PGE has been successfully tested in the determination of UA in human blood serum and urine samples for the first time in the literature.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 891, 3 September 2015, Pages 312–320
نویسندگان
, ,