کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163431 1490940 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
“One-shot” analysis of polybrominated diphenyl ethers and their hydroxylated and methoxylated analogs in human breast milk and serum using gas chromatography-tandem mass spectrometry
ترجمه فارسی عنوان
یک شوتا؟ تجزیه و تحلیل پروتئین های دیفنیل پلی بوروندی و آنالوگ های هیدروکسیل شده و متسول شده آنها در شیر مادر و سرم با استفاده از اسپکترومتری جرمی کروماتوگرافی گاز دوگانه
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A sample preparation method was developed for the “one-shot” simultaneous analysis of PBDEs, OH-BDEs, and MeO-BDEs.
• Method positively correlated with previously published literature on PBDE concentrations in the same paired samples.
• Findings provide insight on the different partitioning behavior of PBDEs, OH-BDEs, and MeO-BDEs in humans.

The presence of polybrominated diphenyl ethers (PBDEs) and their hydroxylated (OH-BDE) and methoxylated (MeO-BDE) analogs in humans is an area of high interest to scientists and the public due to their neurotoxic and endocrine disrupting effects. Consequently, there is a rise in the investigation of the occurrence of these three classes of compounds together in environmental matrices and in humans in order to understand their bioaccumulation patterns. Analysis of PBDEs, OH-BDEs, and MeO-BDEs using liquid chromatography-mass spectrometry (LC-MS) can be accomplished simultaneously, but detection limits for PBDEs and MeO-BDEs in LC-MS is insufficient for trace level quantification. Therefore, fractionation steps of the phenolic (OH-BDEs) and neutral (PBDEs and MeO-BDEs) compounds during sample preparation are typically performed so that different analytical techniques can be used to achieve the needed sensitivities. However, this approach involves multiple injections, ultimately increasing analysis time. In this study, an analytical method was developed for a “one-shot” analysis of 12 PBDEs, 12 OH-BDEs, and 13 MeO-BDEs using gas chromatography with tandem mass spectrometry (GC-MS/MS). This overall method includes simultaneous extraction of all analytes via pressurized liquid extraction followed by lipid removal steps to reduce matrix interferences. The OH-BDEs were derivatized using N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide (TBDMS-MTFA), producing OH-TBDMS derivatives that can be analyzed together with PBDEs and MeO-BDEs by GC-MS/MS in “one shot” within a 25-min run time. The overall recoveries were generally higher than 65%, and the limits of detection ranged from 2 to 14 pg in both breast milk and serum matrices. The applicability of the method was successfully validated on four paired human breast milk and serum samples. The mean concentrations of total PBDEs, OH-BDEs, and MeO-BDEs in breast milk were 59, 2.2, and 0.57 ng g−1 lipid, respectively. In serum, the mean total concentrations were 79, 38, and 0.96 ng g−1 lipid, respectively, exhibiting different distribution profiles from the levels detected in breast milk. This “one-shot” GC-MS/MS method will prove useful and cost-effective in large-scale studies needed to further understand the partitioning behavior, and ultimately the adverse health effects, of these important classes of brominated flame retardants in humans.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 892, 10 September 2015, Pages 140–147
نویسندگان
, , , , , ,