کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163562 1490945 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Optimal design of experiments applied to headspace solid phase microextraction for the quantification of vicinal diketones in beer through gas chromatography-mass spectrometric detection
ترجمه فارسی عنوان
طراحی بهینه ای از آزمایشات کاربردی برای میکرو اکستراکتازی فاز جامد سرامیکی برای اندازه گیری دیکیتون های ناقص در آبجو از طریق تشخیص اسپکترومتر جرم کروماتوگرافی گاز
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Optimization of HS-SPME methodology using optimal design of experiments.
• In-depth study of extraction parameters and analysis of their optimal levels.
• Good results regarding linearity, sensitivity, selectivity, precision and accuracy.
• Automated, easy-to-operate and fast analytical methodology to control VKDs in beer.

Vicinal diketones, namely diacetyl (DC) and pentanedione (PN), are compounds naturally found in beer that play a key role in the definition of its aroma. In lager beer, they are responsible for off-flavors (buttery flavor) and therefore their presence and quantification is of paramount importance to beer producers. Aiming at developing an accurate quantitative monitoring scheme to follow these off-flavor compounds during beer production and in the final product, the head space solid-phase microextraction (HS-SPME) analytical procedure was tuned through experiments planned in an optimal way and the final settings were fully validated. Optimal design of experiments (O-DOE) is a computational, statistically-oriented approach for designing experiences that are most informative according to a well-defined criterion. This methodology was applied for HS-SPME optimization, leading to the following optimal extraction conditions for the quantification of VDK: use a CAR/PDMS fiber, 5 ml of samples in 20 ml vial, 5 min of pre-incubation time followed by 25 min of extraction at 30 °C, with agitation. The validation of the final analytical methodology was performed using a matrix-matched calibration, in order to minimize matrix effects. The following key features were obtained: linearity (R2 > 0.999, both for diacetyl and 2,3-pentanedione), high sensitivity (LOD of 0.92 μg L−1 and 2.80 μg L−1, and LOQ of 3.30 μg L−1 and 10.01 μg L−1, for diacetyl and 2,3-pentanedione, respectively), recoveries of approximately 100% and suitable precision (repeatability and reproducibility lower than 3% and 7.5%, respectively). The applicability of the methodology was fully confirmed through an independent analysis of several beer samples, with analyte concentrations ranging from 4 to 200 g L−1.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 887, 5 August 2015, Pages 101–110
نویسندگان
, , , , ,