کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163590 1490968 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Lateral flow devices for nucleic acid analysis exploiting quantum dots as reporters
ترجمه فارسی عنوان
دستگاه های جریان جانبی برای تجزیه و تحلیل اسید نوکلئیک با استفاده از نقاط کوانتومی به عنوان خبرنگاران
کلمات کلیدی
جریان جانبی، نقاط کوانتومی، بیوسنسور، نانوذرات، اسیدهای نوکلئیک
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Dipstick tests for DNA hybridization assays and genotyping of single-nucleotide polymorphisms.
• Use of quantum dots as reporters.
• Visual detection without the need for expensive instrumentation.
• Simplicity and low-cost of the assays.

There is a growing interest in the development of biosensors in the form of simple lateral flow devices that enable visual detection of nucleic acid sequences while eliminating several steps required for pipetting, incubation and washing out the excess of reactants. In this work, we present the first dipstick-type nucleic acid biosensors based on quantum dots (QDs) as reporters. The biosensors enable sequence confirmation of the target DNA by hybridization and simple visual detection of the emitted fluorescence under a UV lamp. The ‘diagnostic’ membrane of the biosensor contains a test zone (TZ) and a control zone (CZ). The CZ always fluoresces in order to confirm the proper function of the biosensor. Fluorescence is emitted from the TZ, only when the specific nucleic acid sequence is present. We have developed two general types of QD-based nucleic acid biosensors, namely, Type I and Type II, in which the TZ consists of either immobilized streptavidin (Type I) or immobilized oligodeoxynucleotides (Type II). The control zone consists of immobilized biotinylated albumin. No purification steps are required prior to the application of the DNA sample on the strip. The QD-based nucleic acid biosensors performed accurately and reproducibly when applied to (a) the visual detection of PCR amplification products and (b) visual genotyping of single nucleotide polymorphisms (SNPs) in human genomic DNA from clinical samples. As low as 1.5 fmol of double-stranded DNA were clearly detected by naked eye and the dynamic range extended to 200 fmol. The %CV were estimated to be 4.3–8.2.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 864, 15 March 2015, Pages 48–54
نویسندگان
, , , , ,