کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163843 1490993 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Direct analysis of anabolic steroids in urine using Leidenfrost phenomenon assisted thermal desorption-dielectric barrier discharge ionization mass spectrometry
ترجمه فارسی عنوان
تجزیه و تحلیل مستقیم استروئیدهای آنابولیک در ادرار با استفاده از پدیده لیدنفروست، طیف سنجی جرم یونیزاسیون مانع تخلیه دی اکسید کربن
کلمات کلیدی
استروئید آنابولیک، طیف سنج جرم محیطی، پدیده لیدنفروست، تشخیص حساسیت بالا، یونیزاسیون مستقیم، تجزیه و تحلیل ادرار
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Urinary anabolic steroids were detected with high sensitivity using LPTD-DBDI-MS.
• Anabolic steroids were directly ionized using DBDI without any adduct formation.
• Analytical figures of merit are demonstrated using suitable internal standards.

Rapid detection of trace level anabolic steroids in urine is highly desirable to monitor the consumption of performance enhancing anabolic steroids by athletes. The present article describes a novel strategy for identifying the trace anabolic steroids in urine using Leidenfrost phenomenon assisted thermal desorption (LPTD) coupled to dielectric barrier discharge (DBD) ionization mass spectrometry. Using this method the steroid molecules are enriched within a liquid droplet during the thermal desorption process and desorbed all-together at the last moment of droplet evaporation in a short time domain. The desorbed molecules were ionized using a dielectric barrier discharge ion-source in front of the mass spectrometer inlet at open atmosphere. This process facilitates the sensitivity enhancement with several orders of magnitude compared to the thermal desorption at a lower temperature. The limits of detection (LODs) of various steroid molecules were found to be in the range of 0.05–0.1 ng mL−1 for standard solutions and around two orders of magnitude higher for synthetic urine samples. The detection limits of urinary anabolic steroids could be lowered by using a simple and rapid dichloromethane extraction technique. The analytical figures of merit of this technique were evaluated at open atmosphere using suitable internal standards. The technique is simple and rapid for high sensitivity and high throughput screening of anabolic steroids in urine.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 839, 11 August 2014, Pages 1–7
نویسندگان
, , , ,