کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163883 1490960 2015 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of peptides and protein digests by reversed phase high performance liquid chromatography–electrospray ionisation mass spectrometry using neutral pH elution conditions
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Analysis of peptides and protein digests by reversed phase high performance liquid chromatography–electrospray ionisation mass spectrometry using neutral pH elution conditions
چکیده انگلیسی


• RP-HPLC separations of peptides were performed with neutral and acidic pH conditions.
• Immuno-depleted plasma proteins were tryptic digested and separated with 2D-SCX-RPLC.
• Effects of mobile phase composition and pH on peptide selectivity determined.
• RP-HPLC separations of higher selectivity were achieved by neutral pH elution.
• More sensitive protein identifications were obtained by neutral pH elution.

In this study, the advantages of carrying out the analysis of peptides and tryptic digests of proteins under gradient elution conditions at pH 6.5 by reversed-phase liquid chromatography (RP-HPLC) and in-line electrospray ionisation mass spectrometry (ESI-MS) are documented. For these RP separations, a double endcapped, bidentate anchored n-octadecyl wide pore silica adsorbent was employed in a capillary column format. Compared to the corresponding analysis of the same peptides and protein tryptic digests using low pH elution conditions for their RP-HPLC separation, this alternative approach provides improved selectivity and more efficient separation of these analytes, thus allowing a more sensitive identification of proteins at different abundance levels, i.e. more tryptic peptides from the same protein could be confidently identified, enabling higher sequence coverage of the protein to be obtained. This approach was further evaluated with very complex tryptic digests derived from a human plasma protein sample using an online two-dimensional (2D) strong cation-exchange (SCX)-RP-HPLC-ESI-MS/MS system. Again, at pH 6.5, with mobile phases of different compositions, improved chromatographic selectivities were obtained, concomitant with more sensitive on-line electrospray ionisation tandem mass spectrometric (ESI-MS/MS) analysis. As a consequence, more plasma proteins could be confidently identified, highlighting the potential of these RP-HPLC methods with elution at pH 6.5 to extend further the scope of proteomic investigations.

Graphical AbstractFigure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 872, 4 May 2015, Pages 84–94
نویسندگان
, , , , ,