کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1164007 1490986 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Conditions to obtain precise and true measurements of the intramolecular 13C distribution in organic molecules by isotopic 13C nuclear magnetic resonance spectrometry
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Conditions to obtain precise and true measurements of the intramolecular 13C distribution in organic molecules by isotopic 13C nuclear magnetic resonance spectrometry
چکیده انگلیسی


• Evaluation of the trueness and precision criteria of isotopic 13C NMR spectrometry.
• Use of bi-labelled [1,2-13C2]acetic acid to determine the performance of the instrumental response.
• Inter-calibration of the 13C intramolecular composition of acetic acid using the technique GC-Py–irm-MS.

Intramolecular 13C composition gives access to new information on the (bio) synthetic history of a given molecule. Isotopic 13C NMR spectrometry provides a general tool for measuring the position-specific 13C content. As an emerging technique, some aspects of its performance are not yet fully delineated. This paper reports on (i) the conditions required to obtain satisfactory trueness and precision for the determination of the internal 13C distribution, and (ii) an approach to determining the “absolute” position-specific 13C content. In relation to (i), a precision of <1% can be obtained whatever the molecule on any spectrometer, once quantitative conditions are met, in particular appropriate proton decoupling efficiency. This performance is a prerequisite to the measurement of isotope fractionation either on the transformed or residual compound when a chemical reaction or process is being studied. The study of the trueness has revealed that the response of the spectrometer depends on the 13C frequency range of the studied molecule, i.e. the chemical shift range. The “absolute value” and, therefore, the trueness of the 13C NMR measurements has been assessed on acetic acid and by comparison to the results obtained on the fragments from COOH and CH3 by isotopic mass spectrometry coupled to a pyrolysis device (GC-Py–irm-MS), this technique being the reference method for acetic acid. Of the two NMR spectrometers used in this work, one gave values that corresponded to those obtained by GC-Py–irm-MS (thus, the “true” value) while the other showed a bias, which was dependent to the range covered by the resonance frequencies of the molecule. Therefore, the former can be used directly for studying isotope affiliations, while the latter can only be used directly for comparative data, for example in authenticity studies, but can also be used to obtain the true values by applying appropriate correction factors. The present study assesses several key protocol steps required to enable the determination of position-specific 13C content by isotopic 13C NMR, irrespective of the NMR spectrometer: parameters to be adjusted, performance test using [1,2-13C2]acetic acid, generation of correction factors.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 846, 10 October 2014, Pages 1–7
نویسندگان
, , , , , , , , ,