کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1164580 1491000 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reusable conductimetric array of interdigitated microelectrodes for the readout of low-density microarrays
ترجمه فارسی عنوان
آرایه هدایت گرمای قابل استفاده مجدد از میکروالکترودهای بین دیجیتال برای خواندن میکرو آرایه های کم تراکم
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Array of interdigitated electrodes for carrying out up to thirty-six simultaneous analyses.
• Application to the readout of protein microarrays developed on disposable glass slides.
• Compact and inexpensive instrumentation is just required.
• Analytical performance comparable to fluorescent microarray counterparts.
• Detection of boldenone achieving limits of detection below the threshold value set by WADA and EU.

Low-density protein microarrays are emerging tools in diagnostics whose deployment could be primarily limited by the cost of fluorescence detection schemes. This paper describes an electrical readout system of microarrays comprising an array of gold interdigitated microelectrodes and an array of polydimethylsiloxane microwells, which enabled multiplexed detection of up to thirty six biological events on the same substrate. Similarly to fluorescent readout counterparts, the microarray can be developed on disposable glass slide substrates. However, unlike them, the presented approach is compact and requires a simple and inexpensive instrumentation. The system makes use of urease labeled affinity reagents for developing the microarrays and is based on detection of conductivity changes taking place when ionic species are generated in solution due to the catalytic hydrolysis of urea. The use of a polydimethylsiloxane microwell array facilitates the positioning of the measurement solution on every spot of the microarray. Also, it ensures the liquid tightness and isolation from the surrounding ones during the microarray readout process, thereby avoiding evaporation and chemical cross-talk effects that were shown to affect the sensitivity and reliability of the system. The performance of the system is demonstrated by carrying out the readout of a microarray for boldenone anabolic androgenic steroid hormone. Analytical results are comparable to those obtained by fluorescent scanner detection approaches. The estimated detection limit is 4.0 ng mL−1, this being below the threshold value set by the World Anti-Doping Agency and the European Community.

Reusable array of interdigitated electrodes applied to the electrical readout of a protein microarray for boldenone steroid hormone developed on a disposable glass slide.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 832, 17 June 2014, Pages 44–50
نویسندگان
, , , , , , ,