کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1164668 1491006 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cold column trapping-cloud point extraction coupled to high performance liquid chromatography for preconcentration and determination of curcumin in human urine
ترجمه فارسی عنوان
استخراج نقطه ضبط نقطه کروی ستاره همراه با کروماتوگرافی مایع با کارایی بالا برای پیش گیری و تعیین کرکومین در ادرار انسان
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A CCT-CPE coupled to HPLC method was developed for the extraction of curcumin.
• The method is faster than a conventional CPE technique, and no centrifugation is required.
• A response surface method was used for optimization.
• The method was applied to the analysis of curcumin in human urine.

A cold column trapping-cloud point extraction (CCT-CPE) method coupled to high performance liquid chromatography (HPLC) was developed for preconcentration and determination of curcumin in human urine. A nonionic surfactant, Triton X-100, was used as the extraction medium. In the proposed method, a low surfactant concentration of 0.4% v/v and a short heating time of only 2 min at 70 °C were sufficient for quantitative extraction of the analyte. For the separation of the extraction phase, the resulted cloudy solution was passed through a packed trapping column that was cooled to 0 °C. The temperature of the CCT column was then increased to 25 °C and the surfactant rich phase was desorbed with 400 μL ethanol to be directly injected into HPLC for the analysis. The effects of different variables such as pH, surfactant concentration, cloud point temperature and time were investigated and optimum conditions were established by a central composite design (response surface) method. A limit of detection of 0.066 mg L−1 curcumin and a linear range of 0.22–100 mg L−1 with a determination coefficient of 0.9998 were obtained for the method. The average recovery and relative standard deviation for six replicated analysis were 101.0% and 2.77%, respectively. The CCT-CPE technique was faster than a conventional CPE method requiring a lower concentration of the surfactant and lower temperatures with no need for the centrifugation. The proposed method was successfully applied to the analysis of curcumin in human urine samples.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 826, 15 May 2014, Pages 35–42
نویسندگان
, , ,