کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1164993 1491057 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous derivatization and air-assisted liquid–liquid microextraction of some aliphatic amines in different aqueous samples followed by gas chromatography-flame ionization detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous derivatization and air-assisted liquid–liquid microextraction of some aliphatic amines in different aqueous samples followed by gas chromatography-flame ionization detection
چکیده انگلیسی


• Simultaneous derivatization/AALLME was proposed for extraction of aliphatic amines.
• The new method avoided using disperser solvent.
• This method was easy to use and derivatization and extraction were performed simultaneously.
• The method was applied to determine some aliphatic amines in water samples.
• Additional peaks resulting hydrolysis of derivatization agent were observed.

The paper presents a new method based on simultaneous derivatization and air-assisted liquid–liquid microextraction (AALLME) for the extraction and preconcentration of some aliphatic amines prior to gas chromatography-flame ionization detection (GC-FID). Primary aliphatic amines are derivatized and extracted simultaneously by a fast reaction with butylchloroformate (derivatization agent/extraction solvent) under mild conditions. The mixture of butylchloroformate and aqueous sample solution is rapidly sucked into a 10-mL glass syringe and then is injected into a test tube with conical bottom and the procedure is repeated seven times. After centrifuging the resulted cloudy solution, the derivatized analytes in the sedimented phase are determined by GC-FID. The influence of main factors on the efficiency of derivatization/extraction procedure is studied. Under the optimal conditions, the enrichment factors (EFs) for aliphatic amines are obtained in the range of 248–360 and limits of detection (LODs) are between 0.30 and 2.6 μg L−1. The obtained extraction recoveries ranged from 50 to 72% and the relative standard deviation (RSD) was less than 4.8% for intra-day (n = 6) and inter-days (n = 4) precision. The method is successfully applied to determine some aliphatic amines in environmental water samples.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 775, 2 May 2013, Pages 50–57
نویسندگان
, ,