کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1165008 1491061 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrode
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrode
چکیده انگلیسی

This paper describes the fabrication of graphene on glassy carbon electrode (GCE) by electrochemical reduction of graphene oxide (GO) attached through 1,6-hexadiamine on GCE and the simultaneous determination of structurally similar four purine derivatives using the resultant electrochemically reduced GO (ERGO) modified electrode. The electrocatalytic activity of ERGO was investigated toward the oxidation of four important purine derivatives, uric acid (UA), xanthine (XN), hypoxanthine (HXN) and caffeine (CAF) at physiological pH. The modified electrode not only enhanced the oxidation currents of the four purine derivatives but also shifted their oxidation potentials toward less positive potentials in contrast to bare GCE. Further, it successfully separates the voltammetric signals of the four purine derivatives in a mixture and hence used for the simultaneous determination of them. Selective determination of one purine derivative in the presence of low concentrations other three purine derivatives was also realized at the present modified electrode. Using differential pulse voltammetry, detection limits of 8.8 × 10−8 M, 1.1 × 10−7 M, 3.2 × 10−7 M and 4.3 × 10−7 M were obtained for UA, XN, HXN and CAF, respectively. The practical application of the modified electrode was demonstrated by simultaneously determining the concentrations of UA, XN, HXN and CAF in human blood plasma and urine samples.

Figure optionsDownload as PowerPoint slideHighlights
► Glassy carbon electrode was modified with graphene by self assembly method.
► Modified electrode was characterized by Raman spectroscopy.
► Graphene modified electrode separated the voltammetric signals of four purine derivatives.
► Selective and simultaneous determination of four purine compounds were achieved.
► Practical application was demonstrated in human blood serum and urine samples.