کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1165538 1491065 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Battery-triggered ultrasensitive electrochemiluminescence detection on microfluidic paper-based immunodevice based on dual-signal amplification strategy
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Battery-triggered ultrasensitive electrochemiluminescence detection on microfluidic paper-based immunodevice based on dual-signal amplification strategy
چکیده انگلیسی

Dual-signal amplification strategy for ultrasensitive electrochemiluminescence (ECL) multiplexed immunoassay on microfluidic paper-based analytical devices (μ-PADs) was demonstrated. This dual-signal amplification technique was achieved by employing graphene oxide-chitosan/gold nanoparticles (GCA) immunosensing platform and [4,4′-(2,5-dimethoxy-1,4-phenylene)bis(ethyne-2,1-diyl) dibenzoic acid] (P-acid) functionalized nanoporous silver (P-acid/NPS) signal amplification label. For further low-cost and disposable applications, battery-triggered constant-potential ECL (+1.0 V for P-acid label (vs. Ag/AgCl auxiliary electrode)) was applied on this paper-based immunodevice with the aid of a home-made voltage-tunable power device, allowing the traditional electrochemical workstation to be abandoned. We found that two tumor markers could be sequentially detected in the linear ranges of 0.003–20 and 0.001–10 ng mL−1 with the detection limits down to 1.0 and 0.8 pg mL−1, respectively, by simply reversing the connection mode on two working electrodes. The results exhibited excellent precision and high sensitivity of such immunoassay, and it also demonstrated that this battery-triggered ECL paper-based immunodevice could provide a rapid, simple and simultaneous multiplex immunoassay with high throughput, low-cost and low detection limits for point-of-care testing.

GCA as immunosensing platform and P-acid/NPS were prepared to immobilize to Ab1 and Ab2 respectively and combine to fabricate to a novel ECL paper-based immunodevice for detecting PSA and CEA.Figure optionsDownload as PowerPoint slideHighlights
► The as-prepared GCA was employed as immunosensing platform for target capture.
► P-acid/NPS composites were used as signal amplification labels.
► Battery-triggered (constant-potential) ECL detection on this immunodevice.
► The cross-reactivity and cross-talk should be totally eliminated.
► The total immunoassay process could be completed within 15 min.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 767, 12 March 2013, Pages 66–74
نویسندگان
, , , , , ,