کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1165673 1491047 2013 15 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two-dimensional wavelet transform feature extraction for porous silicon chemical sensors
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Two-dimensional wavelet transform feature extraction for porous silicon chemical sensors
چکیده انگلیسی


• The study formulates a novel interrogation/analysis strategy for pSi chemical sensors.
• The strategy includes 2D wavelet analysis to explore the resulting spectral wavelengths.
• We demonstrated greater insights into the transduction mechanisms of the studied sensors.
• Results indicate outstanding performance in the identification and quantification of chemical analytes.

Designing reliable, fast responding, highly sensitive, and low-power consuming chemo-sensory systems has long been a major goal in chemo-sensing. This goal, however, presents a difficult challenge because having a set of chemo-sensory detectors exhibiting all these aforementioned ideal conditions are still largely un-realizable to-date. This paper presents a unique perspective on capturing more in-depth insights into the physicochemical interactions of two distinct, selectively chemically modified porous silicon (pSi) film-based optical gas sensors by implementing an innovative, based on signal processing methodology, namely the two-dimensional discrete wavelet transform. Specifically, the method consists of using the two-dimensional discrete wavelet transform as a feature extraction method to capture the non-stationary behavior from the bi-dimensional pSi rugate sensor response. Utilizing a comprehensive set of measurements collected from each of the aforementioned optically based chemical sensors, we evaluate the significance of our approach on a complex, six-dimensional chemical analyte discrimination/quantification task problem. Due to the bi-dimensional aspects naturally governing the optical sensor response to chemical analytes, our findings provide evidence that the proposed feature extractor strategy may be a valuable tool to deepen our understanding of the performance of optically based chemical sensors as well as an important step toward attaining their implementation in more realistic chemo-sensing applications.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 785, 27 June 2013, Pages 1–15
نویسندگان
, , , , , ,