کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1165805 1491088 2012 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Label-free electrochemical impedance detection of kinase and phosphatase activities using carbon nanofiber nanoelectrode arrays
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Label-free electrochemical impedance detection of kinase and phosphatase activities using carbon nanofiber nanoelectrode arrays
چکیده انگلیسی

We demonstrate the feasibility of a label-free electrochemical method to detect the kinetics of phosphorylation and dephosphorylation of surface-attached peptides catalyzed by kinase and phosphatase, respectively. The peptides with a sequence specific to c-Src tyrosine kinase and protein tyrosine phosphatase 1B (PTP1B) were first validated with ELISA-based protein tyrosine kinase assay and then functionalized on vertically aligned carbon nanofiber (VACNF) nanoelectrode arrays (NEAs). Real-time electrochemical impedance spectroscopy (REIS) measurements showed reversible impedance changes upon the addition of c-Src kinase and PTP1B phosphatase. Only a small and unreliable impedance variation was observed during the peptide phosphorylation, but a large and fast impedance decrease was observed during the peptide dephosphorylation at different PTP1B concentrations. The REIS data of dephosphorylation displayed a well-defined exponential decay following the Michaelis–Menten heterogeneous enzymatic model with a specific constant, kcat/Km, of (2.1 ± 0.1) × 107 M−1 s−1. Consistent values of the specific constant was measured at PTP1B concentration varying from 1.2 to 2.4 nM with the corresponding electrochemical signal decay constant varying from 38.5 to 19.1 s. This electrochemical method can be potentially used as a label-free method for profiling enzyme activities in fast reactions.

Figure optionsDownload as PowerPoint slideHighlights
► We developed an electrochemical method to detect phosphorylation/dephosphorylation.
► Peptides were functionalized on carbon nanofiber nanoelectrode arrays.
► Real-time electrochemical impedance spectroscopy (REIS) showed reversible changes.
► The REIS data of phosphatase showed an exponential decay with a consistent kcat/Km.
► The reaction was analyzed using the Michaelis–Menten heterogeneous enzymatic model.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 744, 26 September 2012, Pages 45–53
نویسندگان
, , , , ,